{"product_id":"coltene-hyflex-rotary-files-4-25mm","title":"Coltene HyFlex NiTi Rotary Files 4% Taper 25mm – Dental Root Canal Endodontic Instruments","description":"\u003cdiv class=\"sc-892bc00b-0 sc-1d8c424f-0 cymOrW\"\u003e\n\u003cdiv class=\"sc-eb36be54-0 jrfDqn\"\u003e\n\u003cdiv class=\"sc-eb36be54-2 fPHBZi\"\u003e\n\u003cdiv class=\"sc-1d8c424f-1 haNrmt\"\u003e\n\u003cdiv class=\"sc-892bc00b-0 sc-892bc00b-4 sc-1d8c424f-2 cymOrW kwxfio izBlDE [\u0026amp;_ul]:!list-disc\"\u003e\n\u003ch4\u003eHyFlex™ Controlled Memory NiTi Files\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHyFlex™ Controlled Memory\u003c\/strong\u003e NiTi Files are created using a unique process that controls the material's memory. This innovation improves performance during use. The files are compatible with crown-down, step-back, or the recommended single length technique. This versatility allows dental professionals to select the ideal method for each clinical case.\u003c\/p\u003e\n\u003ch4\u003eExceptional Resistance to Separation\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e300% more resistance to separation\u003c\/strong\u003e makes the HyFlex CM files stand out in their category. They demonstrate up to 300% higher resistance to cyclical fatigue compared to traditional NiTi files. This increased durability greatly reduces incidences of file separation during endodontic treatment, helping clinicians perform safer procedures.\u003c\/p\u003e\n\u003ch4\u003eSuperior Canal Tracking with No Rebound\u003c\/h4\u003e\n\u003cp\u003eHyFlex Controlled Memory NiTi files use a special manufacturing process to control the material’s memory. The files are extremely flexible without the shape memory effect seen in other NiTi files. This allows them to closely follow the natural canal anatomy, lowering risks such as ledging, transportation, or perforation. The combination of no rebound and extreme flexibility ensures superior canal tracking during use.\u003c\/p\u003e\n\u003ch4\u003eMulti-Use Capability Through Shape Regeneration\u003c\/h4\u003e\n\u003cp\u003eThe shape and strength of files with straightened spirals can be restored via autoclaving. This allows for multiple uses of the same file, lowering costs and environmental impact. However, files that do not return to their original shape after sterilization should be discarded to maintain safety and effectiveness.\u003c\/p\u003e\n\u003ch4\u003eProduct Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConstructed from regenerative Titanium Nickel.\u003c\/li\u003e\n\u003cli\u003ePre-sterilized for immediate clinical use.\u003c\/li\u003e\n\u003cli\u003eExhibit significantly higher resistance to cyclic fatigue than conventional NiTi files.\u003c\/li\u003e\n\u003cli\u003eLow risk of file fracture during procedures.\u003c\/li\u003e\n\u003cli\u003eDesigned to follow canal anatomy to reduce risks of steps, displacements, or perforations.\u003c\/li\u003e\n\u003cli\u003eHighly flexible and break-resistant for durability.\u003c\/li\u003e\n\u003cli\u003eLong life expectancy, thanks to the integrated controlled shape memory that allows shape recovery after heat treatment in the autoclave.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003ctable border=\"1\" width=\"247\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTaper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e4%\u003c\/td\u003e\n\u003ctd\u003e25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePackaging\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eColtene Hyflex File 4% 25mm:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePack of 6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAssorted Pack Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x CM NiTi file 25\/.08, 19mm\u003c\/li\u003e\n\u003cli\u003e1 x CM NiTi file 20\/.04, 25mm\u003c\/li\u003e\n\u003cli\u003e1 x CM NiTi file 25\/.04, 25mm\u003c\/li\u003e\n\u003cli\u003e1 x CM NiTi file 20\/.06, 25mm\u003c\/li\u003e\n\u003cli\u003e1 x CM NiTi file 30\/.04, 25mm\u003c\/li\u003e\n\u003cli\u003e1 x CM NiTi file 40\/.04, 25mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDirections for Use\u003c\/h4\u003e\n\u003ch4\u003eInspection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBefore use, carefully inspect each file for any visible defects or damage.\u003c\/li\u003e\n\u003cli\u003eCheck the expiration date and ensure the files are within the valid period.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePreparation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGather all required equipment, such as handpieces and irrigation solutions.\u003c\/li\u003e\n\u003cli\u003eEnsure the treatment area is properly isolated and fully prepared for the procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFile Selection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelect the appropriate file size based on the anatomy of the canal. Use the size chart for guidance.\u003c\/li\u003e\n\u003cli\u003eConsider the taper and length to meet the specific requirements of your procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSterilization\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the files are sterilized properly before use.\u003c\/li\u003e\n\u003cli\u003eFollow recommended autoclave sterilization protocols to maintain file safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechniques\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHyFlex CM files can be employed using crown-down, step-back, or a single length technique.\u003c\/li\u003e\n\u003cli\u003eChoose the technique that suits the clinical situation and treatment goals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCanal Preparation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStart canal preparation using a gentle, controlled in-and-out motion.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate irrigation during the procedure to remove debris effectively.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControlled Memory Advantage\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUtilize the controlled memory feature to closely follow the canal’s complex anatomy.\u003c\/li\u003e\n\u003cli\u003eBenefit from the file's extreme flexibility without the rebound effect found in other files.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResistance to Separation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTake advantage of the high cyclic fatigue resistance to minimize file separation risk.\u003c\/li\u003e\n\u003cli\u003eMonitor the file condition during treatment closely, replacing any deformed or damaged file.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSterilization After Use\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFiles with straightened spirals can be restored by autoclaving for safe reuse.\u003c\/li\u003e\n\u003cli\u003eDiscard any files that do not regain their original shape after sterilization adequately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePost-Procedure Care\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFollow standard post-procedure care protocols to ensure patient safety and file maintenance.\u003c\/li\u003e\n\u003cli\u003eClean and sterilize instruments correctly for reuse or dispose of them following regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Coltene","offers":[{"title":"Default Title","offer_id":46587532214447,"sku":"Hyflex","price":39.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9755\/3839\/files\/1.-coltene-hyflex-cm-files-4-21mm-1_1.jpg?v=1775994399","url":"https:\/\/dentistrydeal.com\/products\/coltene-hyflex-rotary-files-4-25mm","provider":"Dentistry Deal","version":"1.0","type":"link"}