{"product_id":"woodpecker-obturation-gun","title":"Woodpecker Obturation Gun","description":"\u003cdiv class=\"sc-892bc00b-0 sc-1d8c424f-0 ixfvBk\"\u003e\n\u003cdiv class=\"sc-eb36be54-0 fMhODl\"\u003e\n\u003cdiv class=\"sc-eb36be54-2 jyBgyM\"\u003e\n\u003cdiv class=\"sc-1d8c424f-1 ivzsTD\"\u003e\n\u003cdiv class=\"sc-892bc00b-0 sc-892bc00b-4 sc-1d8c424f-2 ixfvBk jwFGYK kWlpcO [\u0026amp;_ul]:!list-disc\"\u003e\n\u003cp\u003eThe Woodpecker Obturation Gun is an advanced dental device specifically designed to simplify and enhance the process of root canal filling. This innovative tool replaces traditional methods with its exceptional quality control system and user-friendly features, ensuring safe and reliable operation.  Equipped with a range of components, the Woodpecker Obturation Gun offers efficient and effective root canal treatment. Its key features include a gutta-percha injection needle, heat insulation sleeve, heat insulation hood, gutta-percha loading slot, battery level indicator, temperature controls, \"ON\/OFF\" button, pushing ram, and charging base. Each component is meticulously designed and integrated to provide a seamless user experience.\u003c\/p\u003e\n\u003cp\u003eSimplicity and convenience are at the core of this state-of-the-art device. The central control is managed by the \"ON\/OFF\" button, while the temperature control button allows users to choose from preset heating temperatures. Real-time temperature updates and battery level information are displayed on the screen, providing essential data during procedures.\u003c\/p\u003e\n\u003cp\u003eThe Woodpecker Obturation Gun meets rigorous technical parameters, environmental conditions, and storage requirements. It is specifically designed for endodontic filling applications, making it an indispensable tool for any dental practice. Its symmetrical design ensures ease of use for both right-handed and left-handed professionals, providing convenience and comfort throughout procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINDICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHeat up and soften gutta-percha, and fill the gutta-percha into the root\u003cbr\u003ecanal after preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eADVANTAGES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLeft and right display screens\u003c\/li\u003e\n\u003cli\u003eAccording to using habit, choose correspondent screen\u003c\/li\u003e\n\u003cli\u003eErgonomic design\u003c\/li\u003e\n\u003cli\u003eComfortable holding feeling\u003c\/li\u003e\n\u003cli\u003eJapan Panasonic cell\u003c\/li\u003e\n\u003cli\u003eThe battery is reliable and durable for operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExcellent Quality Control System ensures safe and reliable operation\u003c\/li\u003e\n\u003cli\u003eThe temperature control button allows the selection of preset heating temperatures\u003c\/li\u003e\n\u003cli\u003eThe display screen shows the battery level and real-time temperature inside the heating chamber\u003c\/li\u003e\n\u003cli\u003eCharging base and power adapter are provided for convenient charging\u003c\/li\u003e\n\u003cli\u003eCordless design for flexibility during use\u003c\/li\u003e\n\u003cli\u003eMeets technical parameters, environmental conditions, and storage requirements\u003c\/li\u003e\n\u003cli\u003eProper installation and disassembly procedures outlined in the Instruction Manual\u003c\/li\u003e\n\u003cli\u003eDurable construction for longevity and reliable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"217\"\u003e\n\u003ccol width=\"329\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Classification\"}'\u003e \u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Class Ⅱ(AC\/DC power adapter)\"}'\u003eClass Ⅱ(AC\/DC power adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Available  temperatures\"}'\u003e\u003cstrong\u003eAvailable temperatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"150℃→180℃→200℃→230℃\"}'\u003e150℃→180℃→200℃→230℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Time consumption for charging\"}'\u003e\u003cstrong\u003eTime consumption for charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"About 2.5h(3 hours are needle for the first charging\"}'\u003eAbout 2.5h(3 hours are needle for the first charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power Input\"}'\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"AC100V-240V 50\/60Hz 500~800mA\"}'\u003eAC100V-240V 50\/60Hz 500~800mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power Output\"}'\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"DC15V\/1.6A\"}'\u003eDC15V\/1.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Battery capacity(Chargeable battery)\"}'\u003e\u003cstrong\u003eBattery capacity(Chargeable battery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"2000mAh\"}'\u003e2000mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Size\"}'\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"31x152x114mm\"}'\u003e31x152x114mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Storage temperature\"}'\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"20℃ ~ +55℃\"}'\u003e20℃ ~ +55℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Obturation Gun\u003c\/li\u003e\n\u003cli\u003e1 x Power adapter with cable\u003c\/li\u003e\n\u003cli\u003e1 x Gutta-percha injection needle 23G#24mm\u003c\/li\u003e\n\u003cli\u003e1 x Gutta-percha injection needle 23G #28mm\u003c\/li\u003e\n\u003cli\u003e2 x Gutta-percha injection needles 25G #24mm\u003c\/li\u003e\n\u003cli\u003e2 x Heat insulation hood\u003c\/li\u003e\n\u003cli\u003e1 x Heat insulation sleeve for injection needle\u003c\/li\u003e\n\u003cli\u003e2 x Cleaning brush\u003c\/li\u003e\n\u003cli\u003e1 x Pushing ram\u003c\/li\u003e\n\u003cli\u003e1 x Wrench\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDirection To Use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreparation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the Woodpecker Obturation Gun is fully charged by placing it on the charging base and connecting the power adapter.\u003c\/li\u003e\n\u003cli\u003eFamiliarize yourself with the various components of the gun, including the gutta-percha injection needle, heat insulation sleeve, heat insulation hood, gutta-percha loading slot, battery level indicator, temperature controls, \"ON\/OFF\" button, pushing ram, and charging base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLoading Gutta-Percha:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eSlide the gutta-percha loading slot open by pushing the lever or button designated for this purpose.\u003c\/li\u003e\n\u003cli\u003eInsert a gutta-percha cone into the slot and close it securely. Make sure the gutta-percha cone is properly seated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHeating the Gutta-Percha:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eTurn on the Woodpecker Obturation Gun by pressing the \"ON\/OFF\" button. The screen will display the current temperature and battery level.\u003c\/li\u003e\n\u003cli\u003eAdjust the temperature using the temperature control button. Select the appropriate preset heating temperature for your desired outcome.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFilling the Root Canal:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eAfter the gutta-percha has reached the desired temperature, position the gutta-percha injection needle into the root canal.\u003c\/li\u003e\n\u003cli\u003eGently push the pushing ram to release the heated gutta-percha into the canal. Maintain a steady and controlled flow.\u003c\/li\u003e\n\u003cli\u003eMove the injection needle along the canal while delivering the gutta-percha, ensuring even distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring and Adjusting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eKeep an eye on the temperature and battery level displayed on the screen throughout the procedure. Adjust the temperature as needed.\u003c\/li\u003e\n\u003cli\u003eRefill the gutta-percha loading slot when necessary. Follow the loading procedure mentioned in step 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCleaning and Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eAfter completing the root canal filling, turn off the Woodpecker Obturation Gun by pressing the \"ON\/OFF\" button.\u003c\/li\u003e\n\u003cli\u003eDisassemble the components and clean them thoroughly according to the instructions provided in the Instruction Manual.\u003c\/li\u003e\n\u003cli\u003eProperly disinfect and sterilize the components before the next use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodpecker","offers":[{"title":"Default Title","offer_id":46510522269871,"sku":null,"price":345.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9755\/3839\/files\/woodgun2.webp?v=1769160282","url":"https:\/\/dentistrydeal.com\/products\/woodpecker-obturation-gun","provider":"Dentistry Deal","version":"1.0","type":"link"}